All purpose – can be laminated, diecut, slit, formed, or adhesive-coated.
It does not melt. It can be used at both high and low temperature extremes.
Kapton® polyimide films can be used in a variety of electrical and electronic uses.
5 Sheets In Stock
DuPont™ Kapton 300HN A1 general-purpose film has been used successfully in applications at temperatures as low as -269°C (-452°F) and as high as 400°C (752°F). kapton 300hn can be laminated, metallized, punched, formed or adhesive coated. Kapton 300HN is the recommended choice for applications that require an all-polyimide film with an excellent balance of properties over a wide range of temperatures.
Property | Unit | 1 mil 25μm | 2 mil 50μm | 3 mil 75μm | 5 mil 125μm | Test Method |
---|---|---|---|---|---|---|
Ultimate Tensile Strength at 23°C, (73°F) | psi (MPa) | 33,500 (231) | 33,500 (231) | 33,500 (231) | 33,500 (231) | ASTM D-882-91, Method A* |
Ultimate Tensile Strength at 200°C (392°F) | psi (MPa) | 20,000 (138) | 20,000 (138) | 20,000 (138) | 20,000 (138) | ASTM D-882-91, Method A* |
Ultimate Elongation at 23°C, (73°F) | % | 72 | 72 | 78 | 82 | ASTM D-882-91, Method A |
Ultimate Elongation at 200°C (392°F) | % | 83 | 83 | 83 | 83 | ASTM D-882-91, Method A |
Tensile Modulus at 23°C, (73°F) | psi (GPa) | 400,000 (2.76) | 400,000 (2.76) | 400,000 (2.76) | 400,000 (2.76) | ASTM D-882-91, Method A |
Tensile Modulus at 200°C (392°F) | psi (GPa) | 290,000 (2.0) | 290,000 (2.0) | 290,000 (2.0) | 290,000 (2.0) | ASTM D-882-91, Method A |
Density | g/cc | 1.42 | 1.42 | 1.42 | 1.42 | ASTM D-1505-90 |
MIT Folding Endurance | cycles | 285,000 | 55,000 | 6,000 | 5,000 | ASTM D-2176-89 |
Tear Strength-propagating (Elmendorf), N (lbf) | 0.07 (0.02) | 0.21 (0.02) | 0.38 (0.02) | 0.58 (0.02) | ASTM D-1922-89 | |
Tear Strength, Initial (Graves), N (lbf) | 7.2 (1.6) | 16.3 (1.6) | 26.3 (1.6) | 46.9 (1.6) | ASTM D-1004-90 | |
Yield Point at 3% at 23°C, (73°F) | MPa (psi) | 69 (10,000) | 69 (10,000) | 69 (10,000) | 69 (10,000) | ASTM D-882-91 |
Yield Point at 3% at 200°C (392°F) | MPa (psi) | 41 (6,000) | 41 (6,000) | 41 (6,000) | 41 (6,000) | ASTM D-882-91 |
Stress to produce 5% elong. at 23°C, (73°F) | MPa (psi) | 90 (13,000) | 90 (13,000) | 90 (13,000) | 90 (13,000) | ASTM D-882-92 |
Stress to produce 5% elong. at 200°C (392°F) | MPa (psi) | 62 (9,000) | 62 (9,000) | 62 (9,000) | 62 (9,000) | ASTM D-882-92 |
Impact Strength at 23°C, (73°F) | N·cm·(ft lb) | 78 (0.58) | 78 (0.58) | 78 (0.58) | 78 (0.58) | DuPont Pneumatic Impact Test |
Coefficient of Friction, kinetic (film-to-film) | 0.48 | 0.48 | 0.48 | 0.48 | ASTM D-1894-90 | |
Coefficient of Friction, static (film-to-film) | 0.63 | 0.63 | 0.63 | 0.63 | ASTM D-1894-90 | |
Refractive Index (sodium D line | 1.70 | 1.70 | 1.70 | 1.70 | ASTM D-542-90 | |
Poisson’s Ratio | 0.34 | 0.34 | 0.34 | 0.34 | Avg. three samples, elongated at 5, 7, 10% | |
Low temperature flex life | pass | pass | pass | pass | IPC-TM-650, Method 2.6.18 |
*Specimen size 25 x 150 mm (1.6 in); jaw separation 100 mm (4 in), jaw speed, 50mm/min (2 in/min). Ultimate refers to the tensile strength and elongation measured at break. |
Thermal Property | Typical Value | Test Condition | Test Method |
---|---|---|---|
Melting Point | None | None | ASTM E-794-85 (1989) |
Thermal Coefficient of Linear Expansion | 20 ppm/°C, (11 ppm/°F) | -14 to 38°C, (7 to 100°F) | ASTM D-696-91 |
Coefficient of Thermal Conductivity, W/m·K | 0.12, 2.87 x 104 | 296K, 23°C | ASTM F-433-77 (1987) |
Specific Heat, J/g•K (cal/g·°C) | 1.09 (0.261) | ||
Heat Sealability | not heat sealable | ||
Solder Float | pass | IPC-TM-650 Method 2.4.13A | |
Smoke Generation | Dm=<1 | NBS smoke chamber | NFPA-258 |
Shrinkage, % 30 min at 150°C | 0.17 | IPC-TM-650 Method 2.2.4A; ASTM D-5214-91 | |
Shrinkage, % 120 min at 400°C | 1.25 | IPC-TM-650 Method 2.2.4A; ASTM D-5214-91 | |
Limiting Oxygen Index, % | 37–45 | ASTM D-2863-87 |
Glass Transition Temperature (Tg ) | A second order transition occurs in Kapton® between 360°C (680°F) and 410°C (770°F) and is assumed to be the glass transition temperature. Different measurement techniques produce different results within the above temperature range. |
Property Film Gage | Typical Value | Test Condition | Test Method |
---|---|---|---|
Dielectric Strength 25 μm (1 mil) | V/m kV/mm 303, (V/mil) (7700) | 60 Hz 1/4 in electrodes 500 V/sec rise | ASTM D-149-91 |
Dielectric Strength 50 μm (2 mil) | V/m kV/mm 240, (V/mil) (6100) | 60 Hz 1/4 in electrodes 500 V/sec rise | ASTM D-149-91 |
Dielectric Strength 75 μm (3 mil) | V/m kV/mm 201, (V/mil) (5100) | 60 Hz 1/4 in electrodes 500 V/sec rise | ASTM D-149-91 |
Dielectric Strength 125 μm (5 mil) | V/m kV/mm 154, (V/mil) (3900) | 60 Hz 1/4 in electrodes 500 V/sec rise | ASTM D-149-91 |
Dielectric Constant 25 μm (1 mil) | 3.4 | 1 kHz | ASTM D-150-92 |
Dielectric Constant 50 μm (2 mil) | 3.4 | 1 kHz | ASTM D-150-92 |
Dielectric Constant 75 μm (3 mil) | 3.5 | 1 kHz | ASTM D-150-92 |
Dielectric Constant 125 μm (5 mil) | 3.5 | 1 kHz | ASTM D-150-92 |
Dissipation Factor 25 μm (1 mil) | 0.0018 | 1 kHz | ASTM D-150-92 |
Dissipation Factor 50 μm (2 mil) | 0.0020 | 1 kHz | ASTM D-150-92 |
Dissipation Factor 75 μm (3 mil) | 0.0020 | 1 kHz | ASTM D-150-92 |
Dissipation Factor 75 μm (3 mil) | 0.0026 | 1 kHz | ASTM D-150-92 |
Volume Resistivity 25 μm (1 mil) | 1.5 x 1017 | ASTM D-257-91 | |
Volume Resistivity 50 μm (2 mil) | 1.5 x 1017 | ASTM D-257-91 | |
Volume Resistivity 75 μm (3 mil) | 1.4 x 1017 | ASTM D-257-91 | |
Volume Resistivity 125 μm (5 mil) | 1.0 x 1017 | ASTM D-257-91 |
Temperature Range, °C, (°F) | ppm/°C |
---|---|
30–100 (86–212) | 17 |
100–200 (212–392) | 32 |
200–300 (392–572) | 40 |
300–400 (572–752) | 44 |
30–400 (86–752) | 34 |